Sign In
Polure
Favorites

Polyurethane Column Projects and Types

A polyurethane column is the classical column form moulded in rigid polyurethane: shaft, capital and base. It is light and surface-mounted onto the existing structure. This page brings together the types (plain, fluted, twisted; full round and half), the size range and photographs from completed projects.

370 galleries195 products
Polyurethane Ballroom and Event Hall Column Arch Models
Polyurethane Ballroom and Event Hall Column Arch Models

Types: plain, fluted, twisted and pilaster

The shaft surface sets the character. A plain shaft is sober and modern; the vertical channels of a fluted shaft make the column read slimmer and taller; a twisted shaft creates a baroque accent and is produced at 260 cm. Against a wall a half column is used, and on a narrow face a pilaster.
TypeDistinguishing featureWhere it is preferred
Plain columnSmooth shaft, no shadow linesModern facades, plain interiors, pier cladding
Fluted columnVertical channels make it read tallerClassic facades, entrance features, living rooms
Twisted columnHelical shaft, 260 cm lengthBaroque/neoclassical accent, hotel and hall entrances
Full roundFree-standing, seen from all sidesUnder balconies, terraces, open halls
Half columnTwo half shells against a wallCladding existing piers, wall accents
PilasterFlat section, engaged lookNarrow facades, interior wall articulation
Capital (Doric/Ionic/Corinthian)Top order: plain, volute, acanthusThe part that sets the style
BaseSeparates shaft from floor, closes the junctionCompletes every column

Size range and the three-piece logic

Shaft diameters run with a standard length of 240 cm (260 cm twisted). A column is three pieces: shaft, capital and base. Full round sizes read as a square section (200×200 = Ø20) and half sizes as width × full diameter (150×300 = half of Ø30).

Capital orders: Doric, Ionic, Corinthian

The capital sets the style. Doric is plain and geometric and suits transitional interiors. The Ionic capital carries volutes curling to each side (P5220I50, P5230I50). The Corinthian capital with acanthus leaves is the most ornate (P542050, P5220C50) and is chosen for tall living rooms, hotel entrances and event halls. The base separates the shaft from the floor and closes the junction.

Load, steel frame and the cladding rule

Polyurethane columns are decorative and carry no load. Where a load exists an internal steel frame carries it; concrete is never poured inside. When cladding an existing pier, measure its widest point and choose a larger inner diameter. In steel construction, thermal expansion joints are absorbed with elastic mastic.

Related Topics

Polyurethane Column Covers and Decorative Pillar CladdingExterior ColumnsColumn Capitals

Related Products

Related Categories

ColumnsFluted ColumnSpiral ColumnsColumn CapitalsPilaster ColumnsPolyurethane Smooth Column Shaft ModelPolyurethane Fluted Column Model 20x240 cmPolyurethane Spiral Column Shaft ModelPolyurethane Ionic Column Capital ModelClassic Acanthus Leaf Polyurethane Column Capital

Application Gallery

Polyurethane Ballroom and Event Hall Column Arch Models
View Details
Polyurethane Ballroom and Event Hall Column Arch Models
Polyurethane Ballroom Column and Arch Decoration Design
View Details
Polyurethane Ballroom Column and Arch Decoration Design
Polyurethane Wedding Hall Column and Arch Decoration Models
View Details
Polyurethane Wedding Hall Column and Arch Decoration Models
Polyurethane Ceiling and Column Decoration for Wedding Halls and Ballrooms
View Details
Polyurethane Ceiling and Column Decoration for Wedding Halls and Ballrooms
Polyurethane Column and Arch Wedding Venue Stage Decoration
View Details
Polyurethane Column and Arch Wedding Venue Stage Decoration
Polyurethane Classic Exterior Moulding and Window Jamb Designs
View Details
Polyurethane Classic Exterior Moulding and Window Jamb Designs
Classic Polyurethane Column and Ceiling Decoration Designs
View Details
Classic Polyurethane Column and Ceiling Decoration Designs
Polyurethane Columns and Classic Fireplace Wall Decoration
View Details
Polyurethane Columns and Classic Fireplace Wall Decoration
Facade - Neoclassical - Entrance Door - 2000
View Details
Facade - Neoclassical - Entrance Door - 2000
2000
Poliüretan Neo Klasik Giriş Portalı Tasarımı
View Details
Poliüretan Neo Klasik Giriş Portalı Tasarımı
2000
Poliüretan Neo Klasik Dış Cephe Giriş Takı ve Sütun Modelleri
View Details
Poliüretan Neo Klasik Dış Cephe Giriş Takı ve Sütun Modelleri
2000
Poliüretan Neo Klasik Dış Cephe Giriş Portalı Modelleri
View Details
Poliüretan Neo Klasik Dış Cephe Giriş Portalı Modelleri
2000
Poliüretan Neo Klasik Dış Cephe Giriş Kapısı Tasarımları
View Details
Poliüretan Neo Klasik Dış Cephe Giriş Kapısı Tasarımları
2000
Polyurethane Exterior Entrance Door and Trim Designs
View Details
Polyurethane Exterior Entrance Door and Trim Designs
2000
Polyurethane Exterior Window Surrounds and Pilaster Columns
View Details
Polyurethane Exterior Window Surrounds and Pilaster Columns
İZMİR2023
Polyurethane Classic Exterior Window Surround and Column Cladding Designs
View Details
Polyurethane Classic Exterior Window Surround and Column Cladding Designs
BALIKESİR 2023
Polyurethane Exterior Window Surround and Pilaster Column Applications
View Details
Polyurethane Exterior Window Surround and Pilaster Column Applications
ORDU2023
Polyurethane Exterior Window Trims and Pilaster Column Applications
View Details
Polyurethane Exterior Window Trims and Pilaster Column Applications
TEKİRDAĞ2023
Polyurethane Classic Exterior Moulding and Column Designs
View Details
Polyurethane Classic Exterior Moulding and Column Designs
KIRKLARELİ2023
Polyurethane Exterior Classic Villa Window Trim and Column Design
View Details
Polyurethane Exterior Classic Villa Window Trim and Column Design
EDİRNE2023
Polyurethane Exterior Window Trim and Pilaster Column Models
View Details
Polyurethane Exterior Window Trim and Pilaster Column Models
ERZURUM2023
Polyurethane Exterior Window Trim and Column Cladding Models
View Details
Polyurethane Exterior Window Trim and Column Cladding Models
ANKARA2023
Polyurethane Classic Exterior Trim and Column Cladding Models
View Details
Polyurethane Classic Exterior Trim and Column Cladding Models
SİVAS2023
Polyurethane Classic Wall and Ceiling Cladding Models for Wedding Halls
View Details
Polyurethane Classic Wall and Ceiling Cladding Models for Wedding Halls
Polyurethane Ballroom and Wedding Hall Interior Decorations
View Details
Polyurethane Ballroom and Wedding Hall Interior Decorations
Polyurethane Classic Ballroom Ceiling and Wall Decoration Designs
View Details
Polyurethane Classic Ballroom Ceiling and Wall Decoration Designs
Polyurethane Classic Wedding Hall and Ballroom Decoration Designs
View Details
Polyurethane Classic Wedding Hall and Ballroom Decoration Designs
Polyurethane Wedding Hall Ceiling and Wall Moulding Designs
View Details
Polyurethane Wedding Hall Ceiling and Wall Moulding Designs

Related Guides

Column Selection and Installation GuideComplete GuidePolyurethane Decoration Price GuideComplete Guide

Frequently Asked Questions

How many types of polyurethane column are there?

Three: plain, fluted and twisted, each as a full round or half (cladding) column; pilasters are used on narrow faces.

Which sizes are available?

Shaft diameters , standard length 240 cm and 260 cm in the twisted range. Half columns run from 100×200 mm to 300×600 mm.

What is the difference between capital orders?

Doric is plain and geometric, Ionic carries volutes and Corinthian has acanthus leaves and is the most ornate. The capital defines the style of the column.

Do the columns carry load?

No, they are decorative. Where a load exists an internal steel frame carries it, and concrete is never poured inside the column.

Which diameter is needed to clad an existing pier?

Measure the widest point of the pier; the inner diameter of the column must exceed it, otherwise the half shells will not close at the joints.

What is done in rooms taller than 240 cm?

A shaft joint is planned and concealed with a base, collar or band, and the pieces are cross-screwed.

Can they be used outdoors?

Yes. The material absorbs less than 1% water and is dimensionally stable between -100 °C / +80 °C; outdoors it is sealed with an elastic UV-resistant paint.

How is the price calculated?

Shaft, capital and base are separate items, one of each per visible column. Prices cover the product only and goods are ex-works.

Get a price quote for your project

Share your measurements and photos of the application area; we will prepare your quote including products and installation.

Request a QuoteMessage Us on WhatsApp