


Poliüretan 21x42x29 cm Ionic Capital Pilaster Column
Technical Specifications
| Material | Polyurethane |
|---|---|
| Color | White |
| Density | 150-220 kg/m³ (production target ~160 kg/m³) |
| Water Absorption | below 1% |
| Service Temperature | -100 °C / +80 °C |
| Fire Class | B2 (flame retardant) |
| Paintable | Yes |
| Usage | Indoor + Outdoor |
| Water Resistant | Yes |
| Diameter | Ø 21 cm |
| Dimensions | 212 × 424 × 291 mm |
| Sales Unit | piece |
Details
Support
Similar Products(Pilaster Column Ionic Capital)




























An ionic capital for a pilaster column is a decorative architectural element that completes the upper section of a pilaster shaft on interior and exterior surfaces. The P5030I50 model features balanced proportions and the distinctive character of an Ionic capital, completing column compositions around windows, doors, entrances and facades. It is not structural and is installed as a decorative covering over existing concrete, stone, wood or metal surfaces.
The model measures 21 x 42 x 29 cm in width x length x height. Its 21 cm width gives the capital a clear presence on the pilaster surface, while the 42 cm length and 29 cm height create an upper section that reads at both facade and interior scale rather than as a small ornamental piece. The closed-cell PU structure has a density of 150-220 kg/m³. It is lighter than plaster and solid wood, while being harder and better able to retain fine details than EPS foam.
Thanks to its closed-cell structure, water absorption is below 1%; this should not be interpreted as complete water impermeability. The product has high dimensional stability, with no expected shrinkage, expansion or warping under normal installation conditions. It retains its shape between -100 °C and +80 °C. Its B2, difficult-to-ignite structure tends to self-extinguish once the flame source is removed. Since an unpainted surface may yellow outdoors, UV-resistant paint must be used for exterior applications.
The Ionic capital's symmetrical, classically proportioned form creates a defined visual endpoint above the pilaster shaft. It can therefore strengthen vertical architectural emphasis in high-ceilinged rooms, entrance halls and around staircases. On villa facades, it can be used with pilasters surrounding windows or doors. In hotel lobbies, restaurants and formal office entrances, it gives wall surfaces a more architectural arrangement. The product does not carry the load of an existing structural column and cannot replace a structural system.
Before installation, the surface must be clean, dry and sound. If the piece is to be cut with a 45° mitre, the cutting line should be marked carefully. Apply a suitable polyurethane mounting adhesive and position the product; mechanical fixing with screws and the necessary connection hardware is also mandatory. For wide or tall installations, the fixing method should be determined according to the surface and project conditions. Screw heads and joints are filled, smoothed with 180-220 grit sandpaper, then primed and painted with two coats. Silicone adhesive must not be used.
The factory-primed surface is ready for water-based or synthetic paint systems. Additional primer is optional; however, paint manufacturers may not provide a warranty for surfaces painted without their own primer. Polure does not warrant the paint system used and accepts no responsibility for it. Compared with plaster, the product is more resistant to breakage; compared with wood, it is more resistant to moisture, rot and insects. If necessary, it can be repaired with filler and sanding, then adapted to different decorative colours.
- The P5030I50 ionic capital pilaster column is used to define the upper finish of a pilaster shaft
- Installed at the top of decorative pilasters running along a wall in a living room or entrance hall, it creates a classical architectural arrangement around doors, niches or passageways
- In high-ceilinged bedrooms, it can be placed on both sides of a headboard wall; the capital should be aligned with the furniture and positioned at balanced intervals
- In hotel lobbies, restaurants and office entrances, it can serve as an upper element that completes column coverings behind a reception desk
- On villa facades, it can be installed with pilasters around windows and doors to emphasise the entrance axis
- For exterior applications, joints and screw points must be covered with exterior-grade filler, and the final coats must use UV-resistant paint
- It can be applied as a decorative covering over existing structural columns but does not carry structural loads
- Its 21 x 42 x 29 cm dimensions make it a compact capital option that remains clearly visible in a single wall detail
- Remove dust, grease and loose layers from the installation surface, leaving it clean and dry
- Check that the product is positioned on the same vertical axis as the pilaster shaft
- Make any required cuts with a 45° mitre and test the joint surfaces by dry fitting
- Apply polyurethane mounting adhesive only to the back of the piece; silicone adhesive must not be used
- Press the product against the surface, secure it in position and complete the installation with mandatory mechanical fixing using screws
- For wide capitals, select the plugs, screws and fixing intervals according to the nature of the surface
- Fill the screw heads and joint lines, then smooth them with 180-220 grit sandpaper
- Check the factory primer, apply additional primer if required, and finish with two coats of water-based or synthetic paint
- UV-resistant paint must be used outdoors
- A soft, damp cloth is sufficient for surface cleaning
- Remove dust from the Ionic capital's embossed or recessed areas with a soft brush rather than a hard one
- Abrasive powders, solvents, thinners and strong chemicals can damage the paint layer and must not be used
- Outdoors, inspect the painted surface regularly and promptly repair any cracks or opened joints with exterior-grade filler
- For maintenance and touch-up work, choose products compatible with the existing paint system
Can the P5030I50 ionic capital pilaster column be used outdoors?
Yes. The product can be used for exterior architectural decoration. It is suitable for completing the upper sections of pilaster shafts around windows and doors, emphasising a villa entrance or creating a vertical architectural axis on a facade. For outdoor installation, joints and screw points must be covered with exterior-grade filler, the product must not be left unpainted, and the finish must use UV-resistant paint. The product is decorative and does not replace the building's structural system.
How is an ionic capital pilaster column installed and painted?
Position the product on a clean, dry and sound surface, cutting it with a 45° mitre where necessary. Use polyurethane mounting adhesive and complete the installation with mandatory mechanical fixing using screws. Fill the joints and screw heads, then smooth them with 180-220 grit sandpaper. Additional primer may be applied after checking the factory primer. Finish with two coats of water-based or synthetic paint; for exterior applications, choose a UV-resistant system.
What are the dimensions and material properties of the P5030I50 model?
The P5030I50 measures 21 x 42 x 29 cm. Its closed-cell PU structure forms a lightweight, rigid decorative element with a density of 150-220 kg/m³. Water absorption is below 1%, and the product has high dimensional stability. It is not structural and is installed as a covering over an existing surface or column. Since the product has its own weight and connection loads, the installation surface and fixing method must be assessed before installation.
Why choose this pilaster capital instead of plaster or wood?
The product is lighter and less prone to breakage than plaster, while offering greater resistance to moisture, rot and insects than solid wood. It is harder than EPS foam and retains the form of the Ionic capital more reliably. Its closed-cell structure, water absorption below 1% and operating range of -100 °C to +80 °C allow use in a variety of interior and exterior conditions. The surface can also be filled, sanded and repainted.
Is additional primer required for the factory-primed P5030I50?
The factory primer prepares the surface for painting, while additional primer depends on the customer's preference and the selected paint system. Paint manufacturers may not warrant surfaces painted without their own primer, so their technical instructions should be followed. Polure does not warrant the paint products used and accepts no responsibility for them. Before installation, check the surface condition, the primer and the compatibility of the paint system.
Similar Products(Pilaster Column Ionic Capital)




























An ionic capital for a pilaster column is a decorative architectural element that completes the upper section of a pilaster shaft on interior and exterior surfaces. The P5030I50 model features balanced proportions and the distinctive character of an Ionic capital, completing column compositions around windows, doors, entrances and facades. It is not structural and is installed as a decorative covering over existing concrete, stone, wood or metal surfaces.
The model measures 21 x 42 x 29 cm in width x length x height. Its 21 cm width gives the capital a clear presence on the pilaster surface, while the 42 cm length and 29 cm height create an upper section that reads at both facade and interior scale rather than as a small ornamental piece. The closed-cell PU structure has a density of 150-220 kg/m³. It is lighter than plaster and solid wood, while being harder and better able to retain fine details than EPS foam.
Thanks to its closed-cell structure, water absorption is below 1%; this should not be interpreted as complete water impermeability. The product has high dimensional stability, with no expected shrinkage, expansion or warping under normal installation conditions. It retains its shape between -100 °C and +80 °C. Its B2, difficult-to-ignite structure tends to self-extinguish once the flame source is removed. Since an unpainted surface may yellow outdoors, UV-resistant paint must be used for exterior applications.
The Ionic capital's symmetrical, classically proportioned form creates a defined visual endpoint above the pilaster shaft. It can therefore strengthen vertical architectural emphasis in high-ceilinged rooms, entrance halls and around staircases. On villa facades, it can be used with pilasters surrounding windows or doors. In hotel lobbies, restaurants and formal office entrances, it gives wall surfaces a more architectural arrangement. The product does not carry the load of an existing structural column and cannot replace a structural system.
Before installation, the surface must be clean, dry and sound. If the piece is to be cut with a 45° mitre, the cutting line should be marked carefully. Apply a suitable polyurethane mounting adhesive and position the product; mechanical fixing with screws and the necessary connection hardware is also mandatory. For wide or tall installations, the fixing method should be determined according to the surface and project conditions. Screw heads and joints are filled, smoothed with 180-220 grit sandpaper, then primed and painted with two coats. Silicone adhesive must not be used.
The factory-primed surface is ready for water-based or synthetic paint systems. Additional primer is optional; however, paint manufacturers may not provide a warranty for surfaces painted without their own primer. Polure does not warrant the paint system used and accepts no responsibility for it. Compared with plaster, the product is more resistant to breakage; compared with wood, it is more resistant to moisture, rot and insects. If necessary, it can be repaired with filler and sanding, then adapted to different decorative colours.
- The P5030I50 ionic capital pilaster column is used to define the upper finish of a pilaster shaft
- Installed at the top of decorative pilasters running along a wall in a living room or entrance hall, it creates a classical architectural arrangement around doors, niches or passageways
- In high-ceilinged bedrooms, it can be placed on both sides of a headboard wall; the capital should be aligned with the furniture and positioned at balanced intervals
- In hotel lobbies, restaurants and office entrances, it can serve as an upper element that completes column coverings behind a reception desk
- On villa facades, it can be installed with pilasters around windows and doors to emphasise the entrance axis
- For exterior applications, joints and screw points must be covered with exterior-grade filler, and the final coats must use UV-resistant paint
- It can be applied as a decorative covering over existing structural columns but does not carry structural loads
- Its 21 x 42 x 29 cm dimensions make it a compact capital option that remains clearly visible in a single wall detail
- Remove dust, grease and loose layers from the installation surface, leaving it clean and dry
- Check that the product is positioned on the same vertical axis as the pilaster shaft
- Make any required cuts with a 45° mitre and test the joint surfaces by dry fitting
- Apply polyurethane mounting adhesive only to the back of the piece; silicone adhesive must not be used
- Press the product against the surface, secure it in position and complete the installation with mandatory mechanical fixing using screws
- For wide capitals, select the plugs, screws and fixing intervals according to the nature of the surface
- Fill the screw heads and joint lines, then smooth them with 180-220 grit sandpaper
- Check the factory primer, apply additional primer if required, and finish with two coats of water-based or synthetic paint
- UV-resistant paint must be used outdoors
- A soft, damp cloth is sufficient for surface cleaning
- Remove dust from the Ionic capital's embossed or recessed areas with a soft brush rather than a hard one
- Abrasive powders, solvents, thinners and strong chemicals can damage the paint layer and must not be used
- Outdoors, inspect the painted surface regularly and promptly repair any cracks or opened joints with exterior-grade filler
- For maintenance and touch-up work, choose products compatible with the existing paint system
Can the P5030I50 ionic capital pilaster column be used outdoors?
Yes. The product can be used for exterior architectural decoration. It is suitable for completing the upper sections of pilaster shafts around windows and doors, emphasising a villa entrance or creating a vertical architectural axis on a facade. For outdoor installation, joints and screw points must be covered with exterior-grade filler, the product must not be left unpainted, and the finish must use UV-resistant paint. The product is decorative and does not replace the building's structural system.
How is an ionic capital pilaster column installed and painted?
Position the product on a clean, dry and sound surface, cutting it with a 45° mitre where necessary. Use polyurethane mounting adhesive and complete the installation with mandatory mechanical fixing using screws. Fill the joints and screw heads, then smooth them with 180-220 grit sandpaper. Additional primer may be applied after checking the factory primer. Finish with two coats of water-based or synthetic paint; for exterior applications, choose a UV-resistant system.
What are the dimensions and material properties of the P5030I50 model?
The P5030I50 measures 21 x 42 x 29 cm. Its closed-cell PU structure forms a lightweight, rigid decorative element with a density of 150-220 kg/m³. Water absorption is below 1%, and the product has high dimensional stability. It is not structural and is installed as a covering over an existing surface or column. Since the product has its own weight and connection loads, the installation surface and fixing method must be assessed before installation.
Why choose this pilaster capital instead of plaster or wood?
The product is lighter and less prone to breakage than plaster, while offering greater resistance to moisture, rot and insects than solid wood. It is harder than EPS foam and retains the form of the Ionic capital more reliably. Its closed-cell structure, water absorption below 1% and operating range of -100 °C to +80 °C allow use in a variety of interior and exterior conditions. The surface can also be filled, sanded and repainted.
Is additional primer required for the factory-primed P5030I50?
The factory primer prepares the surface for painting, while additional primer depends on the customer's preference and the selected paint system. Paint manufacturers may not warrant surfaces painted without their own primer, so their technical instructions should be followed. Polure does not warrant the paint products used and accepts no responsibility for them. Before installation, check the surface condition, the primer and the compatibility of the paint system.