Poliüretan Ionic Pilaster Column Capital 11x21x15 cm
Technical Specifications
| Material | Polyurethane |
|---|---|
| Surface | Dekoratif, klasik detaylı yüzey |
| Color | White |
| Density | 150-220 kg/m³ (production target ~160 kg/m³) |
| Water Absorption | below 1% |
| Service Temperature | -100 °C / +80 °C |
| Fire Class | B2 (flame retardant) |
| Paintable | Yes |
| Usage | Indoor + Outdoor |
| Water Resistant | Yes |
| Diameter | Ø 11 cm |
| Dimensions | 106 × 212 × 145 mm |
| Sales Unit | piece |
Details
Support
Similar Products(Pilaster Column Ionic Capital)
















The Ionic Pilaster Column Capital is a decorative architectural element designed to complete the upper section of a pilaster shaft. Its classically detailed surface gives pilaster applications integrated with a wall a defined finishing touch. It should be considered a finishing element for interior spaces, façades, and decorative column compositions, not as a structural support.
Made from rigid polyurethane with a closed-cell structure, it has a density of 150-220 kg/m³. Measuring 11x21x15 cm, it creates a controlled transition at the top of a pilaster shaft. Its compact size also makes it suitable for narrow entrance halls, window surrounds, and small-scale decorative columns. The closed-cell structure keeps water absorption below 1%. The product maintains its shape across a temperature range of -100 °C to +80 °C and offers high dimensional stability.
The classic surface design of the Ionic Pilaster Column Capital transforms a plain shaft into a more defined architectural composition. Its Ionic-inspired upper section creates a decorative focal point where the pilaster lines come to an end. The white surface provides a neutral base before application and can be adapted to the project's colour palette with water-based or synthetic paint. Careful cutting and surface preparation are required to preserve the fine decorative details.
The Ionic Pilaster Column Capital can be used on living room walls, in entrance hall arrangements, hotel lobbies, behind shop windows, and in restaurant interiors. At villa entrances or around façade openings, it can be installed with a pilaster shaft to complete window and door compositions. For exterior use, the paint must be UV-resistant. The product does not replace a structural column; it is applied as a decorative covering over an existing surface or structural element.
Before installation, the surface must be clean, dry, sound, and free of dust. Where cutting is required, use 45° mitre cuts. Only polyurethane (PU) mounting adhesive should be used; silicone adhesive is not suitable. In addition to adhesive, the product must be mechanically secured with screws. Fill the joints and screw heads, sand with 180-220 grit abrasive, then apply primer and two coats of paint. Compared with plaster, it is lighter and more resistant to breakage; compared with wood, it offers greater resistance to moisture, decay, and insects.
The factory primer helps prepare the surface for painting; however, paint manufacturers may not provide a warranty for surfaces painted without their own primer. Additional priming is therefore optional and should be assessed according to the selected paint system. Polure does not guarantee paints used with its products and accepts no responsibility for paint performance. With correct installation, suitable paint, and regular surface care, P5015I50 is a decorative finishing element suitable for long-term use in classic pilaster designs.
- The Ionic Pilaster Column Capital is used to create the upper finish of a pilaster shaft
- On living room walls, it can be placed above decorative panels framed by pilaster shafts on both sides
- In entrance halls, it strengthens the classical architectural emphasis around mirrors, doors, or niches
- In commercial spaces such as hotel lobbies, restaurants, and shops, it can be used behind reception desks, around display frames, or in decorative wall compositions
- When installed with a pilaster element at villa entrances and around windows, it adds a structured architectural layer to the façade
- Its 11x21x15 cm dimensions make it a well-proportioned upper element for small- and medium-scale applications
- The white surface can be painted to match the surrounding wall colour
- For exterior applications, UV-resistant paint should be used, and joints and screw points should be filled with exterior-grade filler
- The product is intended solely for decorative use and must not be used as a structural column or support
- The installation surface must be clean, dry, even, and sound
- Remove dust, grease, loose paint, and surface residues, then check the connection with the pilaster shaft
- Make 45° mitre cuts where required
- Apply polyurethane (PU) mounting adhesive to the back of the product and press it into position on the surface
- Adhesive alone is not sufficient; the product must also be mechanically secured with suitable screws
- Fill the screw points and joint lines, then smooth the cured filler with 180-220 grit abrasive
- Finish by applying primer and two coats of paint
- Do not use silicone adhesive
- For exterior applications, cover the connection points with exterior-grade filler and choose UV-resistant paint
- The surface of the Ionic Pilaster Column Capital can be cleaned with a soft, dry, or slightly damp cloth
- Do not use a hard brush, abrasive sponge, or high-pressure water to remove dust
- Avoid solvents, strong chemicals, and cleaning products that may soften the surface
- On exterior applications, inspect the paint surface at regular intervals
- If peeling, cracking, or colour changes appear, clean the surface before repair, remove loose paint, and follow the procedure appropriate for the selected paint system
Can the Ionic Pilaster Column Capital be used outdoors?
Yes, the product can be used for exterior decoration. It must be installed as a decorative covering over a sound surface or an existing structural element; the product itself does not carry structural loads. It must not be left unpainted outdoors and should be coated with UV-resistant paint. Joints and screw points should be filled with exterior-grade filler. Rain, sunlight, freeze-thaw cycles, and surface movement should be considered when selecting the paint system.
How is the Ionic Pilaster Column Capital installed and painted?
Once the surface has been cleaned and dried, make the required cuts with 45° mitre joints. Use polyurethane (PU) mounting adhesive and mechanically secure the product with screws. Fill the joints and screw points, then smooth them with 180-220 grit abrasive. Finish by applying primer and two coats of paint. The factory primer helps paint adhesion; whether an additional primer is needed should be determined according to the paint manufacturer's application system.
What should be known about the product's weight and service life?
The exact weight of P5015I50 may vary according to the product density, mould design, and part geometry, so no estimated kilogram value should be given here. Its rigid closed-cell structure provides a lighter decorative solution than plaster and solid wood. Correct PU adhesive, required mechanical fastening, and suitable filler and paint directly affect installation performance. Service life depends on the installation surface, paint system, cleaning, and exposure to outdoor conditions.
Why is this material preferred for a pilaster capital over plaster or wood?
Rigid PU-based decorative elements are lighter than plaster and more resistant to breakage. Compared with wood, they offer greater resistance to moisture, decay, and insects. The closed-cell body keeps water absorption below 1% and maintains dimensional stability. The surface can also be filled, sanded, and repainted. Even so, the product should not be considered a structural material like wood or stone.
Which pilaster shafts are compatible with P5015I50?
P5015I50 is a capital component designed to complete the upper section of a pilaster shaft. Compatibility can only be determined by checking the dimensions and cross-section; it should not be assumed to fit every similar-looking shaft automatically. Before installation, verify the 11x21x15 cm dimensions and test-fit the connecting surfaces. If a different shaft is used in the project, the installer must assess whether its cross-section, width, and mounting surface are compatible with the capital.
Similar Products(Pilaster Column Ionic Capital)
















The Ionic Pilaster Column Capital is a decorative architectural element designed to complete the upper section of a pilaster shaft. Its classically detailed surface gives pilaster applications integrated with a wall a defined finishing touch. It should be considered a finishing element for interior spaces, façades, and decorative column compositions, not as a structural support.
Made from rigid polyurethane with a closed-cell structure, it has a density of 150-220 kg/m³. Measuring 11x21x15 cm, it creates a controlled transition at the top of a pilaster shaft. Its compact size also makes it suitable for narrow entrance halls, window surrounds, and small-scale decorative columns. The closed-cell structure keeps water absorption below 1%. The product maintains its shape across a temperature range of -100 °C to +80 °C and offers high dimensional stability.
The classic surface design of the Ionic Pilaster Column Capital transforms a plain shaft into a more defined architectural composition. Its Ionic-inspired upper section creates a decorative focal point where the pilaster lines come to an end. The white surface provides a neutral base before application and can be adapted to the project's colour palette with water-based or synthetic paint. Careful cutting and surface preparation are required to preserve the fine decorative details.
The Ionic Pilaster Column Capital can be used on living room walls, in entrance hall arrangements, hotel lobbies, behind shop windows, and in restaurant interiors. At villa entrances or around façade openings, it can be installed with a pilaster shaft to complete window and door compositions. For exterior use, the paint must be UV-resistant. The product does not replace a structural column; it is applied as a decorative covering over an existing surface or structural element.
Before installation, the surface must be clean, dry, sound, and free of dust. Where cutting is required, use 45° mitre cuts. Only polyurethane (PU) mounting adhesive should be used; silicone adhesive is not suitable. In addition to adhesive, the product must be mechanically secured with screws. Fill the joints and screw heads, sand with 180-220 grit abrasive, then apply primer and two coats of paint. Compared with plaster, it is lighter and more resistant to breakage; compared with wood, it offers greater resistance to moisture, decay, and insects.
The factory primer helps prepare the surface for painting; however, paint manufacturers may not provide a warranty for surfaces painted without their own primer. Additional priming is therefore optional and should be assessed according to the selected paint system. Polure does not guarantee paints used with its products and accepts no responsibility for paint performance. With correct installation, suitable paint, and regular surface care, P5015I50 is a decorative finishing element suitable for long-term use in classic pilaster designs.
- The Ionic Pilaster Column Capital is used to create the upper finish of a pilaster shaft
- On living room walls, it can be placed above decorative panels framed by pilaster shafts on both sides
- In entrance halls, it strengthens the classical architectural emphasis around mirrors, doors, or niches
- In commercial spaces such as hotel lobbies, restaurants, and shops, it can be used behind reception desks, around display frames, or in decorative wall compositions
- When installed with a pilaster element at villa entrances and around windows, it adds a structured architectural layer to the façade
- Its 11x21x15 cm dimensions make it a well-proportioned upper element for small- and medium-scale applications
- The white surface can be painted to match the surrounding wall colour
- For exterior applications, UV-resistant paint should be used, and joints and screw points should be filled with exterior-grade filler
- The product is intended solely for decorative use and must not be used as a structural column or support
- The installation surface must be clean, dry, even, and sound
- Remove dust, grease, loose paint, and surface residues, then check the connection with the pilaster shaft
- Make 45° mitre cuts where required
- Apply polyurethane (PU) mounting adhesive to the back of the product and press it into position on the surface
- Adhesive alone is not sufficient; the product must also be mechanically secured with suitable screws
- Fill the screw points and joint lines, then smooth the cured filler with 180-220 grit abrasive
- Finish by applying primer and two coats of paint
- Do not use silicone adhesive
- For exterior applications, cover the connection points with exterior-grade filler and choose UV-resistant paint
- The surface of the Ionic Pilaster Column Capital can be cleaned with a soft, dry, or slightly damp cloth
- Do not use a hard brush, abrasive sponge, or high-pressure water to remove dust
- Avoid solvents, strong chemicals, and cleaning products that may soften the surface
- On exterior applications, inspect the paint surface at regular intervals
- If peeling, cracking, or colour changes appear, clean the surface before repair, remove loose paint, and follow the procedure appropriate for the selected paint system
Can the Ionic Pilaster Column Capital be used outdoors?
Yes, the product can be used for exterior decoration. It must be installed as a decorative covering over a sound surface or an existing structural element; the product itself does not carry structural loads. It must not be left unpainted outdoors and should be coated with UV-resistant paint. Joints and screw points should be filled with exterior-grade filler. Rain, sunlight, freeze-thaw cycles, and surface movement should be considered when selecting the paint system.
How is the Ionic Pilaster Column Capital installed and painted?
Once the surface has been cleaned and dried, make the required cuts with 45° mitre joints. Use polyurethane (PU) mounting adhesive and mechanically secure the product with screws. Fill the joints and screw points, then smooth them with 180-220 grit abrasive. Finish by applying primer and two coats of paint. The factory primer helps paint adhesion; whether an additional primer is needed should be determined according to the paint manufacturer's application system.
What should be known about the product's weight and service life?
The exact weight of P5015I50 may vary according to the product density, mould design, and part geometry, so no estimated kilogram value should be given here. Its rigid closed-cell structure provides a lighter decorative solution than plaster and solid wood. Correct PU adhesive, required mechanical fastening, and suitable filler and paint directly affect installation performance. Service life depends on the installation surface, paint system, cleaning, and exposure to outdoor conditions.
Why is this material preferred for a pilaster capital over plaster or wood?
Rigid PU-based decorative elements are lighter than plaster and more resistant to breakage. Compared with wood, they offer greater resistance to moisture, decay, and insects. The closed-cell body keeps water absorption below 1% and maintains dimensional stability. The surface can also be filled, sanded, and repainted. Even so, the product should not be considered a structural material like wood or stone.
Which pilaster shafts are compatible with P5015I50?
P5015I50 is a capital component designed to complete the upper section of a pilaster shaft. Compatibility can only be determined by checking the dimensions and cross-section; it should not be assumed to fit every similar-looking shaft automatically. Before installation, verify the 11x21x15 cm dimensions and test-fit the connecting surfaces. If a different shaft is used in the project, the installer must assess whether its cross-section, width, and mounting surface are compatible with the capital.