B2 Fire Class in Polyurethane Decorative Profiles

B2 is a classification used for organic building materials under DIN 4102-1. This guide explains the registered fire class of Polure polyurethane decorative profiles and their application conditions.

Polure polyurethane decorative profiles have the registered fire class B2 (DIN 4102-1) and include phosphorus-based flame retardant additive. B2 describes the fire behaviour classification of the material and does not mean that the product is automatically suitable for every application. Facades, escape routes, fireplace surrounds and similar uses must be assessed according to the project conditions.

Short answer: the fire class of Polure polyurethane products

Polure polyurethane decorative profiles have the registered fire class B2 (DIN 4102-1) and include phosphorus-based flame retardant additive.

This information indicates the product classification under DIN 4102-1. Polyurethane profiles are decorative and non-load-bearing; they are not intended to carry loads, televisions or chandeliers.

How are DIN 4102-1 fire classes read?

DIN 4102-1 evaluates building materials according to their fire behaviour within A and B classes.

  • A class refers to mineral or inorganic building materials.
  • B classes are used for organic materials.
  • B2 is the normally flammable class.
  • B1 is the class above B2.
  • B3 is the easily flammable class.

A product class describes the material’s behaviour under test conditions and does not replace all project decisions concerning the application area.

What is B2 not?

B2 is the normally flammable class in DIN 4102-1; it is not B1 or A.

B2 identifies only the classification within DIN 4102-1. The product should be kept away from open flames, high-heat sources and unsuitable installation conditions.

What is the relationship with EN 13501-1?

EN 13501-1 classes are used for the classification of building materials in Europe.

EN 13501-1 classes and DIN 4102-1 classes do not correspond directly. Therefore, B2 information provided under DIN 4102-1 should not be interpreted by directly converting it to another standard.

Use near fireplaces, heat sources and lighting

In fireplaces with a real flame, the polyurethane profile must be installed without direct contact with the heat source.

A suitable heat insulation barrier and sufficient distance are planned for the application. Points exposed to heat must also be assessed in electric fireplace and LED applications. For fireplace surround applications, request technical information from the Polure sales team regarding project conditions and product placement.

How can a fire class document be requested for a project?

A request for a fire class document is assessed according to the building’s purpose of use and the project requirements.

Building regulation conditions for facades, escape routes and similar areas should be reviewed with the project designer. A technical data sheet for Polure products may be requested from the sales team.

Frequently Asked Questions

Can a polyurethane cornice catch fire?

A polyurethane cornice can ignite when it comes into contact with fire or a high-heat source; Polure products have the registered class B2 (DIN 4102-1). The product should be used away from open flames and in accordance with the application conditions.

What does B2 fire class mean?

B2 means the normally flammable class under DIN 4102-1. This class describes the fire behaviour of organic materials under test conditions and does not mean automatic suitability for every project.

What is the difference between B2 and B1?

B1 is the class above B2 within DIN 4102-1, while B2 is the normally flammable class. The difference between the two classes is assessed according to the test and classification conditions of the relevant standard.

Is polyurethane suitable for facade use under fire regulations?

Whether a polyurethane product is suitable for facade use under fire regulations must be assessed by the project designer according to the building type, facade system and project requirements. The technical data sheet and fire class information should be reviewed before installation.

Can polyurethane be used around a fireplace?

A polyurethane decorative profile may be used around a real-flame fireplace without direct contact with the heat source, provided that a suitable insulation barrier and sufficient distance are planned. Points where heat may develop must also be assessed in electric fireplace and LED applications.

What is the purpose of the additive?

The phosphorus-based flame retardant additive is included in the formulation to influence the material’s fire behaviour. Its presence does not replace the product classification; the product must be assessed together with its registered fire class.