


Polyurethane 36x36x348 cm Full Round Column Decor
Technical Specifications
| Material | Polyurethane decorative material |
|---|---|
| Color | White |
| Density | 150-220 kg/m³ |
| Water Absorption | below 1% |
| Dimensional Stability Test | -20 °C / +70 °C |
| Fire Class | B2 (DIN 4102-1) |
| Paintable | Yes |
| Usage | Indoor + Outdoor |
| Water Resistant | Yes |
| Diameter | Ø 36 cm |
| Dimensions | 360 × 360 × 3482 mm |
| Sales Unit | piece |
Details
Support
Similar Products(Full Round Columns)




















The polyurethane P83TDM20C full round column is a decorative architectural element designed to create a classic column effect indoors and outdoors. Its 36x36x348 cm dimensions provide a strong vertical proportion on large surfaces such as high entrance halls, living rooms with a double-height appearance, hotel lobbies and villa facades. The product is decorative; it does not replace a structural column and can be used as architectural cladding around existing concrete or steel supports.
Made with a rigid, closed-cell cast structure, the product has a density of 150-220 kg/m³. This construction offers easier installation than plaster, concrete and solid wood alternatives while helping the profile retain its consistent circular line. Water absorption is below 1%, which helps reduce the risk of moisture-related deterioration. Dimensional stability has been tested from -20 °C to +70 °C.
The clean circular body of the P83TDM20C full column provides a neutral foundation that can be combined with capitals, bases or arch arrangements in an architectural project. Its even cylindrical form allows light to move continuously across the body, creating a regular vertical accent. The factory-primed surface is prepared for water-based or synthetic paint. Paint manufacturers' warranty conditions should be taken into account; the use of an additional primer depends on the customer's preference and the selected paint system.
The full round column can be used in transitions between living and dining areas, wide entrance halls, stairwells, restaurant entrances and hotel reception areas. Outdoors, it can be applied to verandas, terraces, entrance canopies and as column cladding. UV-resistant paint must be used outdoors. Joints and screw points on the facade should be sealed with exterior filler, then finished in accordance with the paint system.
Before installation, the surface must be clean, dry, even and sound. Where cutting is required, use a 45° mitre cut; position the parts with polyurethane (PU) mounting adhesive and mechanically secure them with screws. After filling the joints and connection points, smooth the surface with 180-220 grit sandpaper, then apply primer and two coats of paint. Compared with plaster, it has a lower risk of breakage; compared with wood, it performs better against moisture- and decay-related effects, while offering a harder, more detailed surface than EPS foam.
The 36x36x348 cm P83TDM20C is suitable for projects with high ceilings or large facade scales where a clearly defined column appearance is required. The price may vary according to the scope of application, paint selection and project requirements.
- The P83TDM20C full round column can be used especially in high-ceilinged living rooms and wide entrance halls to emphasise the vertical proportions of the space
- Paired installations at the transition between a living room and dining area can help separate the spaces without building a wall
- Columns used at the foot of a staircase, beside a gallery void or around a large fireplace help create a more orderly classical architectural language
- Hotel lobbies, restaurant entrances, wedding venues and retail reception areas are examples of commercial spaces that can make use of its 348 cm height
- The columns can also be planned as decorative cladding around existing structural columns; however, the product itself does not carry structural loads
- Outdoors, the column can be used at villa entrances, veranda transitions, terrace covers and beneath entrance canopies
- Using two or four columns on the same alignment can make the door axis more prominent
- For exterior applications, UV-resistant paint should be selected, and joints and screws should be sealed with exterior filler
- When selecting a capital and base, the column's 36x36 cm section should be considered together with the proportions of the facade
- For installation of the P83TDM20C full column, first remove dust, grease and loose material from the application surface, then check that it is dry, even and sound
- If cutting is required for the project, mark the cut line carefully and make a 45° mitre cut
- Position the column with polyurethane (PU) mounting adhesive and always secure it mechanically with screws
- Fill the fastener points and joints with suitable filler
- Once the filler has dried, smooth the surface with 180-220 grit sandpaper
- Before painting, primer application should be assessed according to the technical requirements of the selected paint manufacturer
- Apply two coats of paint as the finish
- For exterior applications, use UV-resistant paint and exterior filler
- The surface of the full round column can be cleaned with a soft cloth and suitable non-abrasive cleaning products
- Abrasive wire, stiff brushes and products containing strong solvents should be avoided, as they may damage the paint layer
- In outdoor applications, the painted surface should be inspected periodically
- If cracks appear at joints, screw points or in the paint layer, clean the affected area, repair the filler and renew the paint system
- During paint selection and application, follow the paint manufacturer's recommendations for surface preparation and primer use
Can the P83TDM20C full round column be used outdoors?
Yes, the P83TDM20C is suitable for interior and exterior applications. It can be used at villa entrances, verandas, terrace transitions, beneath entrance canopies and as decorative cladding around existing structural columns. Outdoors, the surface should be protected with UV-resistant paint. Screw points and joint lines should be sealed with exterior filler, and the paint system should be suitable for outdoor conditions. The product is decorative and is not intended to function as a structural column.
How is a full round column installed and painted?
Install it on a clean, dry, even and sound surface. Use a 45° mitre cut where cutting is required. Position the column with polyurethane (PU) mounting adhesive and mechanically secure it with screws. Fill the joints and screw heads, then smooth the surface with 180-220 grit sandpaper. The factory-primed surface can be painted with water-based or synthetic paint. Whether an additional primer is needed should be determined according to the technical instructions for the selected paint system.
How durable and heavy is the P83TDM20C column?
The P83TDM20C has a rigid, closed-cell cast structure and a density of 150-220 kg/m³. Since it is lighter than plaster, concrete, stone and solid wood alternatives, it makes handling and installation easier. Water absorption is below 1%, and dimensional stability has been tested from -20 °C to +70 °C. The product's service life depends on correct installation, a suitable paint system, UV protection outdoors and regular surface maintenance.
Why choose a polyurethane full column over a plaster or wood column?
Polyurethane full columns are lighter than plaster products and less prone to breakage. Compared with wood, they offer advantages against moisture- and decay-related effects. They provide a harder surface than EPS foam alternatives and help the circular column form appear more clearly. Their factory-primed surface can be adapted to different colour schemes. The product is nevertheless decorative, does not provide structural support and requires mechanical fastening.
Which spaces are suitable for a 36x36x348 cm full column?
The 36x36x348 cm size is suitable for high entrance halls, spacious living rooms, stairwells, restaurant reception areas, hotel lobbies and villa facades. Because it is 348 cm high, the project dimensions should be assessed carefully in smaller rooms with standard ceilings. In large spaces, placing two columns opposite each other can define the circulation axis. On a facade, they can be arranged in balanced pairs on either side of an entrance or along a veranda. The capital and base should be selected to match the column section.